The beginning of November 2021, Vietsum Construction Consultancy and Quality Control Joint Stock Company has conducted the service of inspection and safety assessment of surrounding structures at HDBank project – 58 Cach Mang Thang Tam – Bien Hoa – Dong Nai serves to assess the structural status of neighboring works during project construction.
Quality inspection of this work aims to survey details with specialized equipment, accurately determine the damaged locations and assess the safety level of the structure according to Vietnamese standards to conclude the dangerous level of damage of the structure to offer solutions to continue monitoring or repair and strengthen (reinforce) the structure.
Photo: Safety assessment of building structures around a Project
”Based on Vietnam Standard 9381:2012 Guidelines for assessing the level of danger of building structures”
Accordingly, assessing the danger of damage to the structure of the house in order to conclude the state of the house according to the following 4 levels:
– Class A: The bearing capacity of the building structure can satisfy the requirements of normal use, without danger, and the structure of the building is safe. The building is still in normal use, continue to monitor the arising of damage.
– Class B: The bearing capacity of the basic building structure meets the requirements of normal use, especially with components in a dangerous state, but without affecting the load-bearing structure, the work meets the requirements. requires normal use. The building is still in normal use, continue to regularly monitor the arising of damage, and repair the damage.
– Class C: The bearing capacity of a structural structural part cannot meet the requirements of normal use, and a local hazardous situation occurs. The work needs to accurately determine the damage of the work, give a plan to strengthen (reinforce) the structure of the work.
– Class D: The bearing capacity of the load-bearing structure cannot meet the requirements of normal use, the house appears in an overall hazardous situation. The work needs to be inspected to accurately determine the damage of the work, provide solutions for treatment, or dismantle the work.
Photo: Engineer is checking the wall crack length.
Photo: Engineer is checking the wall crack length.
Photo: Engineers are checking the length of cracks in the floor.
Photo: Engineer is ultrasonic checking the width of the wall crack.
Photo: Engineer is ultrasonic checking the width of the wall crack.
Photo: Engineers are ultrasonically checking the reinforcement of concrete columns.
Photo: The engineer is determining the column concrete strength.
When your project shows signs of damage to the construction work (such as subsidence, seepage, rust, peeling, cracks, tilting of structural components, …) please contact us Vietsum Construction Consultancy and Quality Control Joint Stock Company for advice on solutions to assess the actual status of the project, determine the cause, determine the current quality of the structure to have accurate conclusions for your project and use the building safely, safely and effectively operate the project.
/……………………………………………/
Hotline: 090 959 8771 – Mr Nam
– “Vietsum successfully accompanies customers’ workshop”–