Architectural safety inspection, electrical system and fire safety 2021

Architectural safety check; electrical system and fire safety: to determine the quality of the current work, (compare the changes according to the design) calculate, check the operability, evaluate the safety of the factory for operation factory production use.

In recent years, textile and footwear enterprises are implementing international agreements, committing to labor conditions, environmental hygiene and production safety to meet the requirements of long-term development.

In particular, recently, major brands and distributors in the field of textile and garment and footwear have begun to set many requirements for factories on safety conditions for construction structures, system safety. electricity and fire safety as future commercial terms

FACTORY SAFETY INSPECTION PURPOSE:

1. Architectural safety check; electrical system and fire safety to determine the quality of the current work, (compare design changes) calculate, check the operability, evaluate the safety of the factory for the production and use of the factory.

2. Check to determine the safety of vertical wall frames, glass wall frames, insulated panel frames, and rail boxes that are safe for normal use.

3. Check the safety of the system of rolling shutters, trays for unloading pipelines.

Kiểm tra an toàn kiến trúc, hệ thống điện và an toàn cháy nổ

Photo: Check architectural safety, electrical system and fire safety.

/…………………………………………………./

FACTORY SAFETY INSPECTION CONTENTS:

A. INSPECTION AT THE FACTORY:

   – Visually check the current status of the work, Check the difference between the current status and the design documents made.

   – Measure and draw the details of equipment installation and structure, connection details of the factory’s current state.

   – Survey, determine system network structure parameters,  Record power and live load parameters of equipment.

   – Record damage, power generation, live load of equipment.

   – Data acquisition machine: Steel ruler, laser rangefinder, others.

B. MAKING INSPECTION REPORT AT OFFICE:

   – Check the suitability and rationality of the factory’s current state compared to the approved design.

   – Check the compliance with the construction regulations and standards of the State of Vietnam and the applied technical instructions.

   – Assess the safety of the design (through testing, calculation).

   – Evaluate the level of construction design quality, safety level for users.

   – Calculating serving capacity, capacity to supply current demand, new demand.

   – Make a report to assess the safety of the project, give a complete treatment plan. (if)

Hotline: 090 959 8771 – Mr Nam

— “Vietsum successfully accompanies customers’ workshop”

Leave a comment